Surgiseal Electro Surgical Unit

DIATHERMY UNITS FOR MAJOR SURGERY

surgiseal have been designed according to a “manufacturing philosophy” which privileges the easy and immediate comprehension of all the usage/regulation modes, and at the same time guarantees a wide range of performances, an absolute reproducibility and functioning personalization, as well as a maximum safety and reliability.

100 FUNCTION MEMORIES

In order to help the operators and assure the perfect personalization of the performances, the surgiseal allows memorizing and then selecting through a simple button 100 complete functioning programs, which include pre-set programs for the general or the laparoscopic surgery, the endoscopic surgery under liquid, the flexible endoscopic surgery, as well as the simple bipolar mode.

A WIDE RANGE OF CURRENTS TO SATISFY ALL THE OPERATING NEEDS

surgiseal units have got 17 currents: 10 for the monopolar usage, and 7 for the bipolar usage. Three for the monopolar cut, with self-regulation ADC System – constant power and starting impulse control

  • Pure, non-modulated sinusoidal current for the cut without any coagulating effect;
  • Blend 1, modulated and pulsed sinusoidal current for the cut with normal coagulating effect.

These 2 currents, thanks to specific auto-check software, are perfect for all kinds of usage: normal or specialist surgery, laparoscopy, TUR and vaporization, as well as all the applications under liquid.

  • Blend 2, modulated and pulsed current for the cut with a strong coagulating effect spray type for surgery or laparoscopy.

Three for the monopolar cut, with self-regulation APC System – constant voltage and starting impulse control

  • Auto Pure, non-modulated sinusoidal current for the cut without any coagulating effect;
  • Auto Blend, modulated and pulsed sinusoidal current for the cut with normal coagulating effect;
  • Auto Endo, current with alternating phases of cut and coagulation for the flexible endoscopy.

These currents are perfect for the normal surgery, the laparoscopy and the flexible endoscopy, notably when a very delicate effect with a minimum superficial necrosis is desired.

Four for the monopolar coagulation with self-regulation ADC System – constant power

  • Fulg Forced modulated high voltage current with an optimum superficial and deep efficacy, which is suitable both for the direct usage with an active small section electrode and for the indirect usage through an insulated coagulation forceps. It is perfect also to obtain a cut with a strong coagulating effect;
  • PinPoint-Contact, modulated medium voltage current, which is very similar to the previous one, but with a more delicate effect;
  • Soft, modulated low voltage current with a strong deep effect, and no superficial carbonization. It is perfect for the direct usage with coagulation electrodes, or for the indirect usage through an insulated coagulation forceps;
  • Spray, modulated and pulsed very high voltage current, with a very strong superficial effect and a low penetration into the tissues. It is perfect for the direct usage without any contact, with small section electrodes.

Two for the bipolar cut, with self-regulation ADC System – constant power and Starting impulse control

  • Pure, non-modulated pulsed sinusoidal current for the cut;
  • Blend, modulated and pulsed sinusoidal current for the cut with coagulating effect. With laparoscopic forceps, it is also suitable to obtain a strong coagulating effect only.

Thanks to some specific auto-check software, these currents are perfect for all kinds of usage: normal or specialist surgery, laparoscopy, TUR and all other bipolar applications with saline solution.

Thanks to some specific auto-check software, these currents are perfect for all kinds of usage: normal or specialist surgery, laparoscopy, TUR and all other bipolar applications with saline solution.

Two for the bipolar coagulation, with self-regulation APC System – constant voltage

  • Micro CV, non-modulated low voltage current for very delicate coagulations with Soft / Micro Precise effect, a minimum superficial carbonization, and no sticking on the tissues;
  • Micro Auto, identical to Micro CV, but with Auto Start / Auto Stop Impedance Sensing and Start Delay adjustable from 0 to 5 sec. It is perfect for the usage with manual activation, and no need of special forceps with switch device.

Two for the bipolar coagulation, with self-regulation ADC System – constant power

  • Micro HC, current with Standard Forced effect in order to rapidly coagulate the vascularized points and the bleedings during the procedures with saline solution, and use instruments with tips of big dimensions;
  • Macro, modulated and pulsed current with a stronger effect than the Micro HC current.

One for the coagulation / sealing of big vessels, with self-regulation ADC System – constant power

  • Seal HC, pulsed current to coagulate and close the big vessels with a minimum superficial carbonization and no sticking of the tissues. It can be activated through a pedal foot-switch, and thanks to the Auto Stop Impedance Sensing system it is very efficacious and easy to use, in laparoscopy too.

COMPLETE OUTPUT POWER CONTROL

In order to guarantee the best possible efficiency and the minimum side effects, all the output currents are completely self-controlled through a micro-processor with three different systems:

  • ADC System – constant power, which automatically adjusts the powers by verifying the voltage and the current, according to a continuous feed-back in real time (7,000 checks/sec) between the unit and the patient tissues, as well as between the electrode and its rapidity of sliding on the tissues. This system is also necessary to intervene in an efficacious way on many types of tissue or under liquid with the lowest possible powers.
  • APC System – constant voltage, which automatically adjusts the powers, by keeping the voltage – and so the currents electric arc – constant, according to a continuous feed-back in real time (7,000 checks/sec) between the unit and the patient tissues, as well as between the electrode and its rapidity of sliding on the tissues. This system is also necessary to intervene in an efficacious and very delicate way on the operating point with the minimum superficial necrosis.
  • Starting impulse control, which electronically checks the starting pulse of the cut currents, in order to guarantee the maximum efficacy with the lowest possible powers.

ALL POSSIBLE USAGE MODES, TWO MONOPOLAR OUTPUTS AND TWO BIPOLAR OUTPUTS

All models are equipped with: two monopolar outputs, which can be used at the same time by two different operators through the Twin activation device; two bipolar outputs, which are very useful and common today, notably in laparoscopy.

The two monopolar outputs can be activated by three modes:

  • Both of them by the hand-switches placed on the electrodes holder handles, or by the double pedal foot-switch.
  • One by the hand-switches placed on the electrodes holder handle, and the other by the double pedal foot-switch.
  • Both of them by the double pedal foot-switch, or both of them by the hand-switches placed on the electrodes holder handles: one is for electro-surgery, and the other one for electro-surgery with Argon gas.

The two bipolar outputs can always be activated independently from the monopolar ones, by three modes:

  • For the cut or the coagulation, by the double pedal foot-switch.
  • For the coagulation, by selecting the Micro Auto current, through the automatic Auto Start / Auto Stop Impedance Sensing, with a starting delay adjustable from 0 to 5 sec.
  • For the coagulation and the sealing of the big vessels, by selecting the Seal HC current, with activation by the pedal foot-switch and automatic Auto Stop Impedance Sensing.

BETTER PERFORMANCES, MAXIMUM SAFETY

The surgiseal is equipped with an auto-check system at double microprocessor that is the Master / Sleeve System with two Microprocessors at 32 bit. It is characterized by an interconnection in feed-back, a serial communication, as well as a double memorization of the functioning data with validity control CRC at 16 bit, which has got a big operational capacity and can optimize the execution rapidity of all the different functions, which are necessary to guarantee the maximum safety and functionality.

NEUTRAL ELECTRODE CONTROL CIRCUIT “NPCC SYSTEM”

The surgiseal is equipped with a circuit that can verify the connection / contact of the neutral electrodes “non Split” type with a single section and “Split” type with a double section.

With the “non Split” electrodes, the system checks the right connection of the cable: if it is broken / non well connected, the circuit interrupts the delivery of the power and gives a luminous acoustic alarm signal.

With the “Split” electrodes, the system also checks the quality of the contact between the electrode and the patient tissues, by giving progressive alarm signals. If only 80% of the adult standard electrode surface is well connected, it gives the first luminous alarm signal; if the good contact of the electrode decreases to 50%, it gives another luminous alarm signal and automatically reduces the output power to max. 200W. Finally, if the contact is dangerous or the cable is broken / non well connected, the circuit interrupts the delivery of the power with a complete acoustic and luminous alarm signal.